Applications
Dobel film laminated steel sheet is used where the requirements are high regarding aesthetic and robust surfaces. Dobel Aulux is especially suitable for interior applications where fire classifications are required. Typical uses are marine interiors such as wall and ceiling panels for cabins, bathrooms and showers, furniture and doors. But also for office and shop fittings, apartment and detached house doors.
Product description
Dobel Aulux consists of a 150 µm thick PVC film laminated onto metallized steel sheet. The base material in Dobel Aulux is hot-dip galvanized steel. The product is supplied with a removable protective film. A very wide range of single colours and printed patterns, such as wood and textile replicas, are available. The reverse side has as standard a grey paint coating. Dobel Aulux is supplied as coils, cut-to-length sheets or as slit strip. European standard EN 10 169-1 for organic coated sheet is applicable for this product.
Properties
|
Data |
Test method |
| Film thickness |
150 µm |
ISO 2808 |
| Min bending radius |
0 T* |
|
| Adhesion |
No remark |
ISO 1520 |
| Impact resistance |
18 J |
ISO 6272 |
| Max application temp |
80ºC** |
|
* T is the steel sheet thickness
** Temperatures exceeding 80°C may cause discolouration with time
Dimensions
Sheets cut to size
| Thickness (mm) |
Width (mm) |
Length (mm) |
Zn thickness (g/m2/side)
|
| 0.50 – 1.50 |
– 1276 |
– 3500 |
100*, 275 |
* Standard Zn thickness
Maximum bundle weight: 3.0 tonnes
Coils
| Thickness (mm) |
Width (mm) |
Max coilweight (tonnes) |
Zn thickness (g/m2/side) |
| 0.50 – 1.00 |
-1276 |
5.0 |
100*, 275 |
* Standard Zn thickness
Inside diameter: 610 mm or 508 mm
Tolerances
| Thickness* (mm) |
Tolerance (± mm) |
| 0.50 – 0.60 |
0.06 |
| 0.61 – 0.80 |
0.07 |
| 0.81 – 1.00 |
0.08 |
| 1.01 – 1.20 |
0.09 |
| 1.21 – 1.50 |
0.11 |
* According to SS – EN 10 143, the thickness is that of the steel, including the metal coating.
|
Tolerance (mm) |
| Width (mm) |
-0/+6 |
| Length (mm) |
-0/+2 |
Flatness: 6 mm standard deviation.
Straightness: 6 mm maximum deviation on a gauge length of 2 m.
Squareness: Maximum deviation: 1% of the sheet width.
Resistance to chemicals
Dobel Aulux has a good resistance to chemicals. However there are exceptions e.g. certain organic solvents such as aromatics, ketones and chlorinated hydrocarbons.
Cleaning of surface coating
The surface should only be cleaned with mild detergents and persistent stains can normally be removed by using white spirit. After any cleaning operation the surface must be rinsed with fresh water. If alkaline detergents are used, the useful life of the product will be shortened.
Storage and handling
Care should be taken to avoid damage to the coating during manufacture and installation. Scratches and handling damage that cause the coating to be removed, should be repaired, see product sheet “Cleaning, painting and repair of film laminated steel sheet”. Storing of the material outdoors should be avoided.
However, if such storage is not avoidable, the material should be satisfactorily covered and should be stored in such a manner that will ensure good air circulation, in order to avoid the accumulation of moisture.
Environment
SSAB Laminated Steel continues to commit significant resources in order to ensure that our processes are increasingly environmentally friendly. For further information about environmental properties of Dobel, see product sheet ”environmental specification for film laminated steel sheet”. The production of films and the lamination to the steel sheets are performed under controlled conditions.
More than 99% of the emission from our coil coating processes are recovered and incinerated. The resultant heat is recycled to the paint curing process. Film laminated steel can be recovered at the end of its life cycle and represents an important raw material in the production of new steel by remelting. In this melting process, the emissions caused by the metal and paint coats are removed. Film laminated steel should be collected as all other steel sheet, through the normal scrap recovery channels.
Technical service and information
The dimensions and tolerances in the data sheet are standard. Non-standard dimensions and tolerances available on agreement.